1. Strong lightning impulse resistance. The distribution of lightning impulse voltage along the winding initiation affects the damage degree of transformer winding insulation. The distribution of foil winding initiation voltage is close to linear.
2. Strong short-circuit resistance, low-voltage winding copper foil width is the reactance height, low-voltage current according to the balance between winding ampere-turn requirements match, high, low-voltage winding due to short-circuit axial force almost zero.
3. Good resistance to dry cracking. The transformer is made of filler resin and copper foil. The thermal expansion coefficient of insulation material is the closest to that of copper conductor, which effectively prevents coil from cracking. The company has carried out a variety of anti-cracking tests, such as cold-hot alternation test, thermal shock test and rapid aging test. The results show that the technology of the company can meet the requirements of anti-cracking after long-term operation, especially in low temperature, high temperature and wide range of temperature changes.
4. High overload capacity. If the same capacity of dry-type transformer has the same load loss, the cross-section area of copper foil will be correspondingly larger. When the volume increases, the amount of filler resin will be more. Therefore, the winding has a large heat capacity and the transformer has a strong short-term overload capacity.
Fifth, good flame retardant characteristics, the use of filler resin pouring process is conducive to environmental protection, dry-type transformer with maintenance-free, moisture protection, moisture and heat resistance, flame retardant and self-extinguishing characteristics.
6. Low noise, transformer adopt some special structure and design, make the noise greatly reduced, the overall noise level is 10-13dB (A) lower than the national professional standards.
Seven, the loss is low. Compared with the "8" products commonly used in China, the total loss is reduced by 10-15% on average. It has good economic benefits.
Prev:nothing!
Next:Discussion on the future development of HF transformers |
go back |
Guess what you like
Find us
Mobile:+86-18051358828
Tel:0516-86922188
E-mail:LTELEC2008@163.COM
Website:www.ltelec.com.cn
Add:Intersection of North Ring Road and Hongqi Road, Pizhou(Amorphous City)
What you are interested in
[ 2018-10-12 ]
[ 2018-10-12 ]
[ 2018-10-12 ]
[ 2018-10-12 ]